Bscs with uv lamps should be labeled with a uv light source caution sticker.
Biological safety cabinet class 2 uv light.
Contact radsaf uw edu to get a sticker for your cabinet.
The best biosafety cabinets have built in features to protect cabinet users from uv radiation by ensuring that the light is used properly.
For example in a sterilgard the uv germicidal light switch and cabinet lighting can not be turned on simultaneously.
If desired the ultra violet uv light may be turned on.
However if you are going to use one please follow the safety guides below to.
Uv light before working.
Many researchers swear by the use of uv lamps and would never consider using an enclosure without one.
For assistance with disposing of uv bulbs and lamps go to the uw facilities disposal guide website.
For biological safety cabinets with sashes that close the light must only be used.
If uv lights will be used overnight or for extended periods of time while staff are not present the sign should be posted on the outside of the closed door of the room.
Standard operating procedures for biological safety cabinets the purpose of this guideline is to detail the safe operation of biological safety cabinets or bsc in asu laboratories and to ensure adequate containment of biological materials.
Class ii bscs the most common cabinets used in laboratories are designed to provide personnel protection for you and those around you product protection for your samples and environmental protection.
A biological safety cabinet bsc is the primary means of containment developed for working safely with infectious microorganisms.
Thermo scientific 1300 series class ii type a2 biological safety cabinet package promo perform daily applications safely and efficiently with this simple to order package which includes a cabinet stand pre installed uv light and armrests.
These energy efficient cabinets provide both personal and product protection from biological hazards and contamination and can be connected to external exhaust to provide protection for volatile toxic chemicals used in the cabinet.
The most common type of bsc at asu is a class ii.
2 labconco purifier hepa filtered safety enclosure without guardian monitor.
Turn the uv light off after 15 minutes.
On august 29 2019 in articles for decades germicidal uv lamps have been used in class ii biological safety cabinets to keep the biosafety cabinet s interior clean when not in use.
The centers for disease control cdc national institute of health nih and national science foundation nsf all agree that uv lamps are neither recommended nor required in biological safety cabinets.